MD Series
5. Connection
5-22
Screen display time
The display time varies by screen. Displays the screen after the start of end
output.
Menu screen:
46 ms max.
SCHEDULE screen:
112 ms max.
MONITOR screen:
178 ms max.
COMPARATOR screen: 98 ms max.
PRECHECK screen:
69 ms max.
STATUS screen:
46 ms max.
Fault reset waiting time
Time duration until the acceptance of the fault reset after end output,
communication output, and screen display are all complete.
Fault reset waiting time: 5 ms
For the processing time at fault reset, refer to
Screen display at fault
reset
.
・
Screen display at fault reset
Fault reset input time
Input at least 30 ms.
For the timing of the acceptance of the fault reset, refer to
5
Screen
display and communication time
.
Screen display time
Fault reset processing and screen display time.
Screen display: 212 ms max.
Start-waiting time
Time duration required to turn off the start input after screen display is
complete.
Start-waiting time: 5 ms
(ERR RESET)
Fault reset input
Start-waiting time
Screen display,
Processing time