7. Basic Operation
7-2
→
Enter [OFF] to change the schedule.
→
Set the output type of trouble signal to NC.
→
Set the detection start time of no current/no voltage to 0.5 ms.
→
Set the measurement start time to OFF.
→
Set the length of weld time to NORMAL.
6
Move the cursor to COMM and press the cursor key (
Z
) to go to the following screen.
To perform communication, set items referring
to
6. (6)
○
20
COMMUNICATION CONTROL
to
○
23
COMMUNICATION SPEED
.
In this example, set as shown at left not to
perform communication.
Move the cursor to BACK and press the
ENTER key to move to the second screen of
the STATUS screen.
7
Move the cursor to ERROR and press the cursor key (
Z
) to go to the following
screen.
Set the signals (trouble/caution signals) to be
output when a fault occurs.
In this example, all items are set OFF to
output the trouble signal.
ON: Caution signal output; start signal acceptable
OFF: Trouble signal output; start signal unacceptable
Operation on the STATUS screen is now complete.
Press the MENU key to return to the menu screen.
8
Next, select PRECHECK and press the ENTER key.
Set the precheck ON/OFF and precheck conditions.
Operation on the PRECHECK screen is now complete.
Press the MENU key to return to the menu screen.
→
Set the schedule No. to 15.
→
Set the weld time for precheck at 1.00 ms.
→
Set the voltage to 2.00 V.
Set the range of precheck.
(Set a wide range here.)
→
Use the precheck function.