MD Series
4. Name and Functions of Each Section
4-8
4
WELD STAR lamp
Comes on when welding.
The START lamp on the master comes on during the weld sequence
operation, but the WELD STAR lamp on the slave comes on only during
welding.
Notes)
•
In a short welding, it may be hard to see the illumination of the WELD
STAR lamp.
•
Check the welding operation by the START lamp on the master, not the
WELD STAR lamp on the slave.
5
READY lamp
Comes on when the welding current is ready to be supplied to the equipment.
The following conditions must be met for this lamp to come on:
・
No fault is occurring.
・
Not in the middle of charging
Note) The READY lamp on the master indicates the state of all connected
devices, but that on the slave indicates the state of each device only.
6
POWER lamp
Comes on when the power is supplied after the POWER switch is turned on.
Note) This lamp indicate the power state of each device. For the power state
of each device, check the POWER lamp on each device.
7
POWER switch
Turn this switch on to switch the power on.
8
INPUT POWER connector
Connects the power cable (optional).
9
CURR SENS connector (CURR SIG)
Used to connect to the slave. For connection, refer to
5. (2) Connection
between Master and Slave
.
CONTROL connector
Used to connect to the slave. For connection, refer to
5. (2) Connection
between Master and Slave
.