MD Series
6. Explanation of the Screen
6-11
1
CHARGE VOLTAGE
The charging voltage can be fixed.
The settable voltage is 30 V.
2
CURRENT RANGE
This equipment permits selection of the current range according to the
magnitude of the welding current.
Model No.
Number of
connection
Range
Master: 1
Slave: 0
1.00kA/2.00kA/4.00kA/10.0kA
Master: 1
Slave: 1
2.00kA/4.00kA/8.00kA/20.0kA
Master: 1
Slave: 2
3.00kA/6.00kA/12.0kA/30.0kA
Master: 1
Slave: 3
4.00kA/8.00kA/16.0kA/40.0kA
Master: 1
Slave: 4
5.00kA/10.0kA/20.0kA/50.0kA
Master: 1
Slave: 5
6.00kA/12.0kA/24.0kA/60.0kA
Master: 1
Slave: 6
7.00kA/14.0kA/28.0kA/70.0kA
Master: 1
Slave: 7
8.00kA/16.0kA/32.0kA/80.0kA
Master: 1
Slave: 8
9.00kA/18.0kA/36.0kA/90.0kA
Master: 1
Slave: 9
10.0kA/20.0kA/40.0kA/100kA
Master: 1
Slave: 10
11.0kA/22.0kA/44.0kA/110kA
MD-A10000A
Master: 1
Slave: 11
12.0kA/24.0kA/48.0kA/120kA
MD-B5000A
Master: 1
Slave: 1
1.00kA/2.00kA/4.00kA/10.0kA
3
SCHEDULE MODE
Switches between the 1-step and 2-step weld sequences.
When 2-step welding is unnecessary, select 1-step welding. Since there are
fewer items to be set for 1-step welding, this will make the screen display
easier to see.
SINGLE
1-step weld sequence
DOUBLE
2-step weld sequence
Summary of Contents for MD Series