MD Series
9. External Communication Function
9-14
3) Specified code No.: S02 (SCHEDULE screen)
Used when SCHEDULE MODE on the STATUS screen is DOUBLE.
In case of SINGLE, use Specified code No. S01.
Data strings: When reading Device No. 01 and Schedule No. 008
Host PC -> MD series
#01R008S02[CR][LF]
MD series -> Host PC
!01008S02: 0100, 1.00, 5.00, 1.00, 2.00, 1.00, 4.00, 1.00, 100, kA,
A B
C D
E F G
H I
J
2.00, 3.00, 1.00, 1.50 [CR][LF]
K L
M N
Item
Character
string
Content Range
Increment/
Decrement
A
****,
SQ: Squeeze time
0000 to 9999[ms]
1
*.**,
*1
0.00 to 9.99[ms]
0.01
B
**.*,
*2
U1: Upslope 1 time
00.0 to 99.9[ms]
0.1
*.**,
*1
0.00 to 9.99[ms]
0.01
C
**.*,
*2
W1: Weld 1 time
00.0 to 99.9[ms]
0.1
*.**,
*1
0.00 to 9.99[ms]
0.01
D
**.*,
*2
D1: Downslope 1 time
00.0 to 99.9[ms]
0.1
*.**,
*1
0.00 to 9.99[ms]
0.01
E
**.*,
*2
CL: Cool time
00.0 to 49.9[ms]
0.1
*.**,
*1
0.00 to 9.99[ms]
0.01
F
**.*,
*2
U2: Upslope 2 time
00.0 to 99.9[ms]
0.1
*.**,
*1
0.00 to 9.99[ms]
0.01
G
**.*,
*2
W2: Weld 2 time
00.0 to 99.9[ms]
0.1
*.**,
*1
0.00 to 9.99[ms]
0.01
H
**.*,
*2
D2: Downslope 2 time
00.0 to 99.9[ms]
0.1
I
***,
HD: Hold time
000 to 999[ms]
1
J **,
Unit of current value
kA: Current value in kA
kA -
*.**,
*3
0.00 to 9.99[kA]
*6
0.01
**.*,
*4
00.0 to 99.9[kA]
*6
0.1
K
****,
*5
W1: Weld 1 current
0000 to 0999[kA]
*6
1
*.**,
*3
0.00 to 9.99[kA]
*6
0.01
**.*,
*4
00.0 to 99.9[kA]
*6
0.1
L
****,
*5
W2: Weld 2 current
0000 to 0999[kA]
*6
1
M
*.**,
W1: Weld 1 voltage
0.00 to 9.99[V]
0.01
N
*.**
W2: Weld 2 voltage
0.00 to 9.99[V]
0.01
Summary of Contents for MD Series