Screen display and communication time (Common to MD series)
・
When a fault and caution do not occur during welding
*1: For the timing of the end signal, refer to
1
MD-A series
and
2
MD-B
series
.
Communication output time
Communication output of monitor value. Outputs after the start of end
output.
When COMMUNICATION MODE on the STATUS screen is B MODE
9600 bps of communication speed: 86 ms max.
19200 bps of communication speed: 47 ms max.
38400 bps of communication speed: 26 ms max.
When COMMUNICATION MODE on the STATUS screen is C MODE
9600 bps of communication speed: 136 ms max.
19200 bps of communication speed: 72 ms max.
38400 bps of communication speed: 39 ms max.
Screen display time
The display time varies by screen. Displays the screen after the start of end
output.
Menu screen:
14 ms max.
SCHEDULE screen:
80 ms max.
MONITOR screen:
145 ms max.
COMPARATOR screen: 66 ms max.
PRECHECK screen:
37 ms max.
STATUS screen:
14 ms max.
(END)
(GOOD)
*1
Start input
Welding current
Communication output time
Screen display time
Start-waiting time
End output
Normal output