MD Series
5. Connection
5-15
*3: When a fault or caution occurs in precheck welding, welding is not
performed in W1 and W2 and the fault signal or the caution signal is
output. The selection of fault signal or caution signal can be changed
on the ERROR SETTING screen. At this time, the end signal and the
normal signal are not output.
*4: Monitor calculation time (10 ms)
*5: For the output time of end signal and normal signal, refer to
4
External output signal
. For the processing time of screen display
time, communication output time, etc., refer to
5
Screen display and
communication time
.
*6: When the monitor value is within the setting range, the normal signal is
output. When the monitor value is outside the range or a fault occurs,
a fault signal or caution signal is output. The selection of fault signal or
caution signal can be changed on the ERROR SETTING screen.
*7: The weld force signal cannot be controlled with this device. Control it
by PLC or the like. For the timing of weld force, refer to
6
Weld force
signal
.