9. External Communication Function
9-13
2) Specified code No.: S01 (SCHEDULE screen)
Used when SCHEDULE MODE on the STATUS screen is SINGLE.
In case of DOUBLE, use Specified code No. S02.
Data strings: When reading Device No. 01 and Schedule No. 008
Host PC -> MD series
#01R008S01[CR][LF]
MD series -> Host PC
!01008S01: 0100, 1.00, 5.00, 1.00, 100, kA, 2.00, 1.00 [CR][LF]
A B C D E F
G H
Item
Character
string
Content Range
Increment/
Decrement
A
****,
SQ: Squeeze time
0000 to 9999[ms]
1
*.**,
*1
0.00 to 9.99[ms]
0.01
B
**.*,
*2
UP: Upslope time
00.0 to 99.9[ms]
0.1
*.**,
*1
0.00 to 9.99[ms]
0.01
C
**.*,
*2
WE: Weld time
00.0 to 99.9[ms]
0.1
*.**,
*1
0.00 to 9.99[ms]
0.01
D
**.*,
*2
DS: Downslope time
00.0 to 99.9[ms]
0.1
E
***,
HD: Hold time
000 to 999[ms]
1
F **,
Unit of current value
kA: Current value in kA
kA -
*.**,
*3
0.00 to 9.99[kA]
*6
0.01
**.*,
*4
00.0 to 99.9[kA]
*6
0.1
G
****,
*5
WE: Current value
0000 to 0999[kA]
*6
1
H
*.**
WE: Voltage value
0.00 to 9.99[V]
0.01
*1: When WELD TIME on the STATUS screen is NORMAL.
*2: When WELD TIME on the STATUS screen is LONG.
*3: When CURRENT RANGE on the STATUS screen is *.**kA.
*4: When CURRENT RANGE on the STATUS screen is **.*kA.
*5: When CURRENT RANGE on the STATUS screen is ***kA.
*6: Range depends on CURRENT RANGE on the STATUS screen.