MD Series
9. External Communication Function
9-2
(2) Single-Directional Communication B Mode
(COMMUNICATION MODE on STATUS Screen is B MODE)
1
1-step welding (When SCHEDULE MODE on the STATUS screen is set to SINGLE)
Data strings: M: W1, 01, 5.00, 4.50, 4.50, 4.00, 18.0, 0.89 [CR]
A B C D E F G H I J
Ex.) M: W1,01,5.00,4.50,4.50,4.00,18.0,0.89[CR]
Item
Character
string
Content Range
A
M:
Monitor value sending code
M: (fixed)
B
W1,
Welding code (1-step welding)
W1 (fixed)
C
**,
Schedule No.
01 to 31
*.**,
*1
0.00 to 9.99[kA] ,----
*4
**.*,
*2
00.0 to 99.9[kA] ,----
*4
D
***,
*3
Peak value
000 to 999[kA] ,---
*4
*.**,
*1
0.00 to 9.99[kA] ,----
*4
**.*,
*2
00.0 to 99.9[kA] ,----
*4
E
***,
*3
WELD: Current
Average value
000 to 999[kA] ,---
*4
F
*.**,
Peak value
0.00 to 9.99[V] ,----
*4
G *.**,
WELD: Voltage
Average value
0.00 to 9.99[V] ,----
*4
**.*,
*1
00.0 to 99.9[kW] ,----
*4
H
***,
*2*3
WELD: Power average value
000 to 999[kW] ,---
*4
I
*.**
WELD: Resistance average value
0.00 to 9.99[m
Ω
] ,----
*4
J [CR]
CR
code
0DH
(fixed)
*1: When CURRENT RANGE on the STATUS screen is *.**kA.
*2: When CURRENT RANGE on the STATUS screen is **.*kA.
*3: When CURRENT RANGE on the STATUS screen is ***kA.
*4: When the value exceeds the display range.