![Alstom SHPM 101 Service Manual Download Page 225](http://html1.mh-extra.com/html/alstom/shpm-101/shpm-101_service-manual_2908927225.webp)
SERVICE MANUAL
R5888C
QUADRAMHO
Chapter 5
Page 5 of 24
d) The detection of pole dead.
e) The weak infeed feature.
Select test option 43 (W = 4, Y = 3) all the LEDs now have a different function
from that on the nameplate. Apply volts in turn to each voltage input and check
that the LED indicated lights when 49 volts is applied and does not when 40
volts is applied. If preferred the precise pick-up can be determined and the
drop-off should be within 10% of that value.
Level detector
Terminals injected
LED marking
A phase
1Z 1–4
A
B phase
1Z 2–4
B
C phase
1Z 3–4
C
Note:
During test option checks, only the LEDs mentioned are of concern in a
particular test, others may be on and can be ignored; however, a full table
is given in Figure 3.
4.4.2
Fixed current level detector checks
(i) Low set current level detectors
Each phase current is monitored and the setting is changed by the value of K1
and K2 selected on module 1, the most sensitive setting is 5%
I
n
.
Current setting =
5
x
4.8
x
I
n
amps (
±
10%)
100
K1 + K2
I
n
= relay rated current
The scheme logic uses the information in:
a) Gating the comparators to limit the system impedance ratio up to which the
relay functions.
b) The switch-on-to-fault feature.
c) The detection of pole dead.
Keep test option 43 selected and inject current into each pair of phase
terminals, on the left hand side of the 1Y test block, in turn. Determine the pick-
up as indicated below, the drop-off should be within 10% of actual pick-up.
Level detector
Terminals injected
LED marking
A phase
1Y 1–2
Z3
B phase
1Y 3–4
Aided trip
C phase
1Y 5–6
SOFT
Note:
Refer to 4.4.3(i) as it is convenient to combine the tests.
(ii) High set current level detectors
These are only used in the blocking scheme or the weak infeed feature which
can be used in conjunction with the permissive overreach scheme.
If these schemes are not to be used or are not likely to be selected in the future
this test need not be done.
Current setting =
12.1
x
4.8
x
I
n
amps (
±
10%)
100
K1 + K2
Summary of Contents for SHPM 101
Page 1: ...Service Manual Quadramho Distance Protection Type SHPM 101...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 13: ...Quadramho Distance Protection Type SHPM 101 Service Manual Chapter 1 Application...
Page 14: ......
Page 44: ......
Page 56: ......
Page 208: ......
Page 209: ...Quadramho Distance Protection Type SHPM 101 Service Manual Chapter 3 Electronic Module Housing...
Page 210: ......
Page 211: ...Quadramho Distance Protection Type SHPM101 Service Manual Chapter 4 Installation...
Page 212: ......
Page 214: ......
Page 216: ......
Page 217: ...Quadramho Distance Protection Type SHPM101 Service Manual Chapter 5 Commissioning Instructions...
Page 218: ......
Page 266: ......
Page 280: ......
Page 282: ......
Page 285: ...Quadramho Distance Protection Type SHPM 101 Service Manual Chapter 6 Problem Analysis...
Page 286: ......
Page 288: ......
Page 316: ......
Page 317: ...Quadramho Distance Protection Type SHPM 101 Service Manual Chapter 7 Relay Identification...
Page 318: ......
Page 320: ......
Page 323: ...Quadramho Distance Protection Type SHPM 101 Service Manual Chapter 8 Special Variations...
Page 324: ......
Page 326: ......
Page 332: ......
Page 335: ......