![alphatronics AlphaCom XL Service Manual Download Page 26](http://html.mh-extra.com/html/alphatronics/alphacom-xl/alphacom-xl_service-manual_2906562026.webp)
Service manual AlphaCom XL transceiver Rev. 1.4 10-08-2011
Blz. 26/74
Status screen
After you have logged in as the supervisor (admin) a status menu will appear on your screen. In the status
menu information is displayed of the most important options in the AlphaCom XL. On the left-hand side of
the status menu various menu buttons can be found. Via these menu buttons you can access the various
submenu‟s to change settings. The various submenu‟s will be explained in the next chapters of this manual.
The information displayed in the status menu is refreshed every 10 seconds to provide the most up to date
information at all times.
Possible status information displayed for the transceivers:
Disabled:
The transceiver is not configured.
Not in use:
The transceiver is assumed to be programmed as a backup transceiver and is not operational
yet..
Busy:
The transceiver is busy establishing a connection of sending a message.
Ready:
The connection is operational. There are no messages in the buffer.
Error:
There has been no connection with the central station for over 90 seconds
.