Enter Your Values Here
Load Initial Configuration Values
Chapter 7
7-9
Worksheet 7C (continued)
Hold Configuration Command Block (HDC)
Control Word ProSet 600 Addr. Value
Description
Units
HDC05
N44:181
1000
Minimum ERC PercentageCavity Pressure
Percent
8
HDC06
N44:182
1000
Minimum ERC PercentageRam (Screw) Pressure
Percent
8
HDC09
N44:185
*
Output #1 Setoutput Value During Profile
Percent Signal Output
4
HDC10
N44:186
*
Output #2 Setoutput Value During Profile
Percent Signal Output
4
HDC11
N44:187
*
Output #3 Setoutput Value During Profile
Percent Signal Output
4
HDC12
N44:188
*
Output #4 Setoutput Value During Profile
Percent Signal Output
4
HDC17
N44:193
0
Output #1 Accel Ramp Rate During Profile
Percent Signal Output per Second
5
HDC18
N44:194
0
Output #2 Accel Ramp Rate During Profile
Percent Signal Output per Second
5
HDC19
N44:195
0
Output #3 Accel Ramp Rate During Profile
Percent Signal Output per Second
5
HDC20
N44:196
0
Output #4 Accel Ramp Rate During Profile
Percent Signal Output per Second
5
HDC25
N44:201
0
Output #1 Decel Ramp Rate During Profile
Percent Signal Output per Second
5
HDC26
N44:202
0
Output #2 Decel Ramp Rate During Profile
Percent Signal Output per Second
5
HDC27
N44:203
0
Output #3 Decel Ramp Rate During Profile
Percent Signal Output per Second
5
HDC28
N44:204
0
Output #4 Decel Ramp Rate During Profile
Percent Signal Output per Second
5
HDC33
N44:209
*
Output #1 Setoutput Value at Endof Profile
Percent Signal Output
4
HDC34
N44:210
*
Output #2 Setoutput Value at Endof Profile
Percent Signal Output
4
HDC35
N44:211
*
Output #3 Setoutput Value at Endof Profile
Percent Signal Output
4
HDC36
N44:212
*
Output #4 Setoutput Value at Endof Profile
Percent Signal Output
4
HDC41
N44:217
0
Ram (screw) Pressure Minimum Control Limit
Pressure
3
HDC42
N44:218
*
Ram (screw) Pressure Maximum Control Limit
Pressure
3
HDC43
N44:219
*
Selected Ram (screw) Pressure Valve, Output for Minimum Percent Signal Output
4
HDC44
N44:220
*
Selected Ram (screw) Pressure Valve, Output for Maximum Percent Signal Output
4
HDC45
N44:221
0
Cavity Pressure Minimum Control Limit
Pressure
1
HDC46
N44:222
*
Cavity Pressure Maximum Control Limit
Pressure
1
HDC47
N44:223
*
Selected Cavity Pressure Valve, Output for Minimum
Percent Signal Output
4
HDC48
N44:224
*
Selected Cavity Pressure Valve, Output for Maximum
Percent Signal Output
4
HDC49
N44:225
100
Proportional Gain for Ram (screw) Pressure Control
None
HDC50
N44:226
400
Integral Gain for Ram (screw) Pressure Control
Inverse Time (algorithm)
6
HDC51
N44:227
0
Derivative Gain for Ram (screw) Pressure Control
Time (algorithm)
7
HDC52
N44:228
100
Proportional Gain for Cavity Pressure Control
None
HDC53
N44:229
400
Integral Gain for Cavity Pressure Control
Inverse Time (algorithm)
6
HDC54
N44:230
0
Derivative Gain for Cavity Pressure Control
Time (algorithm)
7
HDC57
N44:233
0
Profile High Ram (screw) Pressure Alarm Setpoint
Pressure
3
HDC58
N44:234
0
Profile High Cavity Pressure Alarm Setpoint
Pressure
1
1
Pressure
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00000 to 20000 PSI
00.00 to 99.99 inches per second
0000 to 9999 PSI
00.00 to 99.99
0000.0 to 2000.0 Bar
000.0 to 999.9 millimeters per second
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse Time (Algorithm)
7
Time (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 minutes (ISA)
00.00 to 99.99 minutes (ISA)
00.00 to 99.99
00.00 to 99.99 seconds (AB)
00.00 to 99.99 seconds (AB)
* Refer to the appropriate section later in this chapter for information on this parameter