Span Your Valves
Chapter 9
9-25
We recommend that you span your plastication RPM valve for optimum
plastication performance in three parts:
Confirm critical values
Span your plastication RPM control valve
Test valve linearity with a plastication RPM vs. time profile
Important: You may omit the subsection Span Your Plastication RPM
Control Valve below if you have information from molding machine OEMs
or hydraulic valve manufacturers on spanning the working range of valves.
If available for your machine’s plastication RPM valve, enter valve
spanning values into RPM control limits PLC45-48 and proceed to Test
Valve Linearity. First confirm your critical values.
Confirm Critical Values
Important: Confirm that all entries you made for configuration values
(chapter 7) and profile values (chapter 8) are as follows:
On Worksheet Confirm Your Configuration
With These Words or Bits
ProSet Addr
7D
(chapter 7)
QDC module output to which you connected
your plastication RPM control valve
PLC02B02, B01, B00
B38/402400
Setoutput values for unselected valves
PLC0912 = your values
N44:365368
All ramping is disabled with zero ramp rates
PLC1720 = 0
PLC2528 = 0
N44:373376
N44:381384
Endofprofile Setoutput values
PLC3336 for zero output
N44:389392
RPM limits:
Minimum RPM Control Limit
Maximum RPM Control Limit
Selected RPM Valve, Output for Min
Selected RPM Valve, Output for Max
PLC45 = 0
PLC46 = max attainable screw RPM
PLC47 = your value
PLC48 = your value
N44:401
N44:402
N44:403
N44:404
8C
(chapter 8)
Logical bridge to stop and set outputs before
postdecompression
PPC03B08 = 1
B38/488
Openloop control
PPC04B03 = B02 = 1
B38/499, 498
Expert Response Compensation (ERC) = Off
PPC04B11 = B10 = 1
B38/507, 506
RPM setpoints
PPC09,13, 17, 21, 25, 29, 33, 37, 41,
45, 49 all equal to 1/2 max screw RPM
start @ N44:425
end @ N44:465
Time setpoints
PPC12,16,20,24,28,32,36,40,44,48
all equal to one second (100)
start @ N44:428
end @ N44:464
Shot size
PPC62 = typical for your machine
N44:478
Set New Values for the RPM vs. Time Profile
On Worksheet Set this Configuration
With These Words or Bits
ProSet Addr
8C
RPM vs Time algorithm
PPC03B01 = B00 = 1
B38/480481
Download the PPC block using the download procedure from chapter 4.
Span Your Plastication
RPM Valve