Enter Your Initial Values Here
Jog Your Machine
Chapter 5
5-8
Worksheet 5. B
Clamp & Eject Jog Configuration Values for QDC Module in Inject Mode
Control Block
Word
ProSet 600 Addr. Value
Description
Units
Clamp, Forward Jog
JGC33
N40:89
Set Output Values Output #1
% Signal Output
1
JGC34
N40:90
Output #2
% Signal Output
1
JGC35
N40:91
Output #3
% Signal Output
1
JGC36
N40:92
Output #4
% Signal Output
1
Clamp, Reverse Jog
JGC41
N40:97
Set Output Values Output #1
% Signal Output
1
JGC42
N40:98
Output #2
% Signal Output
1
JGC43
N40:99
Output #3
% Signal Output
1
JGC44
N40:100
Output #4
% Signal Output
1
Ejector, Advance Jog
JGC49
N40:105
Set Output Values Output #1
% Signal Output
1
JGC50
N40:106
Output #2
% Signal Output
1
JGC51
N40:107
Output #3
% Signal Output
1
JGC52
N40:108
Output #4
% Signal Output
1
Ejector, Retract Jog
JGC57
N40:113
Set Output Values Output #1
% Signal Output
1
JGC58
N40:114
Output #2
% Signal Output
1
JGC59
N40:115
Output #3
% Signal Output
1
JGC60
N40:116
Output #4
% Signal Output
1
1
% Signal Output
00.00 to 99.99 %