Chapter
2
2-1
Install the QDC Module
This chapter guides you through the following installation procedures:
record I/O ranges
set module jumpers
key your I/O chassis
install your QDC module
wire I/O devices to your QDC module
ground your system
plan for E-Stops and Machine Interlocks
To match your QDC module to your I/O devices, record the I/O ranges of
your I/O devices on Worksheet 2-A. You will use this information in this
chapter for hardware configuration (setting jumper plugs) and in chapter 4
to configure the module’s inputs and outputs with software.
Circle or check the I/O ranges on Worksheet 2-A. Cross off I/O not used.
Worksheet 2A
Record I/O Ranges
I/O Connection:
Voltage 1:
Voltage 2:
Current:
Input 1 (Screw position)
0 to 10 Vdc
1 to 5 Vdc
4 to 20 mA
Input 2 (Screw pressure)
0 to 10 Vdc
1 to 5 Vdc
4 to 20 mA
Input 3 (Screw RPM)
0 to 10 Vdc
1 to 5 Vdc
4 to 20 mA
Input 4 (Cavity pressure)
0 to 10 Vdc
1 to 5 Vdc
4 to 20 mA
Output 1
10 to 10 Vdc
0 to 10 Vdc
4 to 20 mA
Output 2
10 to 10 Vdc
0 to 10 Vdc
4 to 20 mA
Output 3
10 to 10 Vdc
0 to 10 Vdc
4 to 20 mA
Output 4
10 to 10 Vdc
0 to 10 Vdc
4 to 20 mA
Chapter Objectives
Record I/O Ranges