System Operation:
Inject Mode 0 0
Select Units
0 = English
1 = metric
Code:
Your value
Required initial value
loaded by ProSet 600
0 or 1
Select Input 1 (Screw Position) Range
Select Input 2 (Screw Pressure) Range
Select Input 3 (Screw RPM) Range
Select Input 4 (Cavity Pressure) Range
Input Range
0 - 10 vdc
0
0
1 - 5 vdc
0
1
4 - 20 mA
1
0
Not connected
1
1
Code:
Your value
Required initial value
loaded by ProSet 600
0 or 1
Appendix
A
A-1
Blank Worksheets
Workshet 3A
Select Module Parameters
Control Word MCC02Bxx
15
14 13 12
11
10
09 08 07 06 05 04 03 02 01 00
ProSet 600 Addr. B34/bit
543 542 541 540 539 538 537 536 535 534 533 532 531 530 529 528
Value
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
Example: If you select Inject operation with English units:
MCC02 = 00000000 00001000
Worksheet 3B
Select Input Ranges for your Sensors
Control Word MCC03Bxx
15
14 13 12 11
10
09 08 07 06 05 04 03 02 01 00
ProSet 600 Addr. B34/bit
559 558 557 556 555 554 553 552 551 550 549 548 547 546 545 544
Value
1
1
1
1
1
1
1
1
Example: If you select an input range of 4-20mA for all four inputs,
MCC03 = 11111111 10101010.