Ethernet/IP
The controller will accept a connection from an Ethernet/IP master. The controller has two connection
assemblies. One for the controller
’
s output image (Assembly Instance 100). The default size of this is
34 bytes. If fastening results are not included then the size is 2 bytes. And one for the controller
’
s input
image (Assembly Instance 112) with a size of 32 bytes.
Logic I/O
The controller has two status bytes of outputs (Assembly instance 100).
Controller Outputs
Bit
7
6
5
4
3
2
1
0
Byte
0
Tool
Ready
Tool
Enable
1
Bypass
Batch
Complete
Status
NOK
Status
OK
Byte
Bit
Name
Function
0
0-7
PSET
Set the active parameter set of 1-32. If 0 the active parameter set is left
unchanged.
1
0
Tool Enable
If PLC Enable is 0 this input is ignored. If PLC Enable is 1 this bit can be used
to enable or disable the tool.
1-3
Not used
4
Pause
Setting Pause to 1 cause the light stack to strobe. Setting it to 0 put the light
stack back into its normal operation.
5
White Flash
Setting White Flash to 1 cause the light stack to flash the white light. Setting it
to 0 put the light stack back into its normal operation.
6
PLC Enable
Setting PLC Enable to 1 allows the Tool Enable bit. Setting it to 0 disables the
Tool Enable function.
7
Not used
2-11
0-7
Sequence Number
10 character Sequence Number.
12-31
0-7
Serial Number
20 character Serial Number.
Networking