5
Figure 4
Main Display Panel
1
—Rundown Feedback Indicators
A—ACCEPT—
Green LED indicates OK rundown
B—TORQUE—Steady red indicates HI, flashing red indicates LO
C—ANGLE—Steady yellow indicates HI, flashing yellow indicates LO
D—CYCLE—Blue LED indicates tool is in rundown cycle
2
—Primary Display Field—Displays Parameter Set Target or Rundown torque
3
—Secondary Display Field—Selectable Display Choices (Angle etc
…)
4
—Programmable Display Selection Buttons
A—Optional Display Access—Accesses the Programmable Options menu
B—NEXT—Scrolls through the different display options for the Secondary Display
C—SET—Sets the selected display option in the Secondary Display
5
—CHANGE PSET—Scrolls upwards through programmed Parameter Sets
6
—PSET Indicator—displays PSET that is currently operating
7
—IR PORT ENABLED—Future function, not currently enabled
Dimensions
1
2
3
7
6
5
4
A
B
C
A
B
C
D
Inches / Millimeters