29
Networking
Profibus/DeviceNET
The controller can have an optional Profibus or DeviceNET interface. These interfaces are accom-
plished through the use of a serial bridge. The serial bridge is provided by MKS Instruments, Inc . See
the latest MKS documentation for details on sending and receiving messages.
Logical I/O
The controller has five status bytes of outputs.
Controller Outputs
Bit
7
6
5
4
3
2
1
0
Byte
0
Tool
Ready
Tool
Enable
1
Bypass
Batch
Complete
Msg
Received
Status
NOK
Status OK
2
3
Buzz Slow
Buzz Fast
Red
Yellow
Green
Blue
White
4
Pause
Red
Flashing
Yellow
Flashing
Green
Flashing
Blue
Flashing
White
Flashing
Byte
Bit
Name
Function
0
0
Tool Enable
The enabled state of the tool.
1
Tool Ready
On if the tool is ready to run. Will be off if tool is disabled or there is a fault
on the controller.
2-7
Not used
1
0
Status OK
Rundown status on for an accept. This bit is timed and will be on for ½
second.
1
Status NOK
Rundown status on for a reject. This bit is timed and will be on for ½
second.
2
Msg Received
On to indicate a message has been received from the MKS module and the
inputs have changed. This bit is timed and will be on for ½ second.
3
Batch Complete
Indicates the batch is complete. Will go off when batch is reset or when the
tool enable is turned off.
4
Bypass
State of the bypass input.
5-7
Not used
2
0-7
Not used
3
0-6
Light Tower Status
Bitwise status of the Light Tower lights.
7
Not used
4
0-5
Light Tower Status
Bitwise status of the Light Tower lights.
6-7
Not used
Controller Inputs
Bit
7
6
5
4
3
2
1
0
Byte
0
PSET
1
PLC
Enable
White
Flash
Pause
Tool
Enable
2-11
Sequence Number
12-31
Serial Number