13
Accessing Quick Start Parameter Sets
From the MAIN MENU, press
1
for
SETUP PSET
Press
1
for
QUICK START
The following text will be displayed on the KDM display screen:
Choose from
EDIT PSET
or
CONFIG PSET. See the following sections for instructions on editing or
configuring Quick Start parameter sets.
Editing Quick Start Parameter Sets
Depending on the number of Parameter Sets that have previously been programmed into the iEC Controller,
the user will have the option of choosing from 1 to 8 parameter sets to edit.
Press the number of the Parameter Set that is to be edited. The following text will be displayed on the KDM
display screen:
To change the target torque value in .1 unit increments press
To change the target torque value in 1.0 unit increments press
After the target torque is entered correctly, press
Verify that the correct parameter set is active by
observing the
PSET Indicator
on the Main Display
Panel. If the desired parameter set is not active,
press
CHANGE PSET
to cycle through the available
parameter sets until the appropriate set is displayed.
The tool is now ready to be run to the appropriate target torque value.
Using the Optional Keypad Display Module (KDM)
2
8
or
+
2
or
+
8
Summary of Contents for iEC
Page 1: ...AcraDyne iEC DC Tool Controllers User Guide...
Page 35: ...35 Appendix B KDM Menu Structures Main Menu Structure Parameter Set up Menu...
Page 36: ...36 APPENDIX B KDM Menu Structures Administration Menu...
Page 45: ...45 Notes...
Page 46: ...46 Notes...