26
Networking
Chrysler PFCS
The controller has the ability to connect to the Chrysler PFCS network. Once the controller is on the
local network there are several parameters that must be set to work correctly.
1.
Server IP Address:
This is the IP address of the Chrysler server. If the server is on another
subnet you will also have to verify the gateway in the Ethernet settings.
2.
Server Port Number:
This is the TCP port the server is listening on for a new connection.
3.
Ack Time Out:
This is the amount of time the controller will wait for an acknowledge message
from the server. The default is 3 seconds.
4.
No. Retries:
The number of retries the controller will attempt before disconnecting. The default
value is 3.
5.
Reconnect Time Out:
The amount of time the controller will wait before attempting to re
-
connect
to the server. The default value is 20 seconds.
6.
Connection Inactivity Time:
The amount of time the controller will wait between connection at-
tempts. The default value is 120 seconds.
7.
Auto Machine Id:
If set to
“
Yes
”
(default) the machine ID will be provided by the Chrysler PFCS
server upon connection. If set to
“
No
”
the machine ID is entered per parameter set on the
“
Advanced
”
tab on the web interface. This will result in each parameter set having its own ID.
Summary of Contents for iEC
Page 1: ...AcraDyne iEC DC Tool Controllers User Guide...
Page 35: ...35 Appendix B KDM Menu Structures Main Menu Structure Parameter Set up Menu...
Page 36: ...36 APPENDIX B KDM Menu Structures Administration Menu...
Page 45: ...45 Notes...
Page 46: ...46 Notes...
Page 47: ...47 Notes...