Chapter 3
73
Theory of Operation
Theory of Operation
T
h
eo
ry o
f Oper
ation
•
Hold
Holds at the end of the waveform
•
Stop
Stops playback
•
Resume
Resumes playback at the point in the waveform that play was held or
stopped
The Waveform Advance, Scenario Advance, Waveform Jump, and Scenario
Jump triggers are only available through the programatic interfaces.
Synchronous Triggers
01Triggers are registered into the N6030A Series AWGs using the SYNC
clock. The SYNC clock is nominally at the sample clock frequency divided
by 8. However, at lower sample rates an internal variable modulus prescaler
selects other binary divide ratios: 8, 4, 2, and 1. In general, the SYNC clock
frequency is always in the range of 78.13 MHz to 156.25 MHz. The input
clock frequency ranges and prescaler divide ratios are as specified in
Table 3-1
:
It is necessary to insure that the correct timing relationships are achieved to
guarantee consistent synchronous trigger operation. The trigger input must
occur within a valid window with respect to the SYNC clock. The window is
specified by two times: Twin_low —the minimum trigger delay after the
prior SYNC clock edge; and Twin_up — the minimum trigger setup before
the next SYNC clock edge. These are specified for the trigger input relative
Table 3-1
Synchronous Triggers
Sample Clock Frequency
SYNC Clock Prescaler Divide Ratio
625 MHz - 1.25 GHz
8
312.5 MHz – 625 MHz
4
156.25 MHz – 312.5MHz
2
100 MHz – 156.25 MHz
1
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com