102
Chapter 4, GPIB Commands
COMPensation Subsystem
COMPensation[:RFG1]:TEMPerature:FREQuency?
ëû
[{0|1|2|3|4|5|
<numeric>
[HZ|KHZ|MAHZ|MHZ|GHZ]}]
This command returns the frequency required at the FROM DUPLEX OUT port
for the temperature compensation for the RF signal generator to provide the
optimum output level accuracy. If the frequency band or value is not specified,
the frequency value specified by the
RX:OUTP:FREQ
is used. (Query only)
0:
800 to 859 MHz band (Compensation frequency: 840 MHz)
1:
859 to 960 MHz band (Compensation frequency: 880 MHz)
2:
1710 to 1785 MHz band (Compensation frequency: 1750 MHz)
3:
1805 to <1850 MHz band (Compensation frequency: 1830 MHz)
4:
1850 to 1910 MHz band (Compensation frequency: 1880 MHz)
5:
1930 to 1990 MHz band (Compensation frequency: 1960 MHz)
<numeric>:
800 to 859 MHz, 859 to 960 MHz, 1710 to 1785 MHz, 1805 to
1850 MHz, 1850 to 1910 MHz, 1930 to 1990 MHz (Compensation
frequency is rounded off to 840 MHz, 880 MHz, 1750 MHz,
1830 MHz, 1880 MHz, or 1960 MHz.) If the entered value is out of
range, the value is rounded off to the appropriate limit value. (The
default unit is “Hz”.)
Supply the signal whose frequency and level are returned by this command and
the
COMP:TEMP:LEV?
command to the FROM DUPLEX OUT port. Then
execute the
COMP:TEMP:EXEC?
command to execute the RF generator
temperature compensation.
•
Response to the Query
{numeric (Hz)} <new line><^END>
Summary of Contents for 83236B
Page 7: ...vii...
Page 10: ...x...
Page 14: ...Contents 14 Error Message 154 Glossary 161...
Page 30: ...30 Chapter 1 General Information Other Information...
Page 123: ...123 5 S pecifications Specifications...
Page 137: ...137 A F requency Conversion Tables Appendix A Frequency Conversion Tables...
Page 140: ...140 Appendix A Frequency Conversion Tables Frequency Conversion for Signal Generation...
Page 141: ...141 B M anual Changes Appendix B Manual Changes...