150
© 2002 ADTRAN, Inc.
61200600L1-1A
Section 5 DLP-007
Total Access 600R System Manual
DLP-007
1. Connect to the unit using the
CRAFT
interface.
If you are not already connected to the unit’s
CRAFT
interface (either with a
VT100 compatible terminal or with a PC running VT100 emulation software), follow the procedure in
DLP-001,
Connecting the Terminal or PC to the CRAFT Port
. Connecting to the
CRAFT
interface lim-
its the upgrade procedure to XMODEM Only.
2. Log in to the unit.
Log in to the unit (see DLP-002,
3. Go to the
S
YSTEM
U
TILITY
menu and select the
U
PGRADE
F
IRMWARE
menu; press <Enter>.
4. Go to the
T
RANSFER
M
ETHOD
menu and select
XMODEM
.
5. Select
S
TART
T
RANSFER
to start the update. Enter
Y
to confirm the upgrade.
6. From the terminal emulation software, begin the XMODEM upload by using the appropriate command
sequence. If necessary, refer to the terminal emulation software documentation for help.
Also, when specifying the filename, ensure that the file transferred is the one provided by ADTRAN.
Otherwise, the update will not complete successfully. This may take several minutes.
Because XMODEM data is being transferred in-band through the menu interface, the VT100 menus of
the unit will be inoperable from the
CRAFT
interface. You can cancel the update at any time within the
terminal emulation software. (Please consult the documentation provided by the terminal emulation
software to determine how to do this.)
7. When the update has successfully completed, the following messages will display:
Verifying downloaded FLASH image...
Erasing FLASH...
Programming FLASH...
FLASH programmed successfully.
The unit will restart immediately, and the user may then log back into the system.
Alternately, if the unit is part of a management cluster connected to the local network, you may use a
PC connected to the network to Telnet into the unit. By utilizing the
10/100B
ASE
T
port, the unit may
be quickly upgraded using TFTP provided there is a TFTP server on the local network. The unit can
also be upgraded across the WAN using TFTP provided there is a TFTP server accessible to the unit.
The unit ships with ADTRAN Utilities software, which includes a TFTP server. See DLP-008,
Upgrading the Firmware Using TFTP
, for more details.
Perform the Steps Below in the Order Listed
Summary of Contents for TOTAL ACCESS 600R
Page 4: ...4 2002 ADTRAN Inc 61200600L1 1A Revision History This is the first issue of this manual...
Page 16: ...Section 1 System Description Total Access 600R System Manual 16 2002 ADTRAN Inc 61200600L1 1A...
Page 128: ...Section 5 DLP Index Total Access 600R System Manual 128 2002 ADTRAN Inc 61200600L1 1A...
Page 134: ...134 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 002 Total Access 600R System Manual...
Page 138: ...138 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 003 Total Access 600R System Manual...
Page 144: ...144 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 005 Total Access 600R System Manual...
Page 152: ...152 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 007 Total Access 600R System Manual...
Page 160: ...160 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 009 Total Access 600R System Manual...
Page 180: ...180 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 015 Total Access 600R System Manual...
Page 190: ...Section 6 ADTRAN Utilities Total Access 600R System Manual 190 2002 ADTRAN Inc 61200600L1 1A...
Page 192: ...Section 7 MIB Total Access 600R System Manual 192 2002 ADTRAN Inc 61200600L1 1A...
Page 196: ...Section 7 MIB Total Access 600R System Manual 196 2002 ADTRAN Inc 61200600L1 1A...