Total Access 600R System Manual
Section 4 User Interface Guide
61200600L1-1A
© 2002 ADTRAN, Inc.
67
I
NTERFACES
(T1[0]) > S
TATUS
> A
LARMS
> C
URRENT
A
LARMS
Displays the current alarms on the T1 interface. An asterisk in a field indicates that an alarm is active.
I
NTERFACES
(T1[0]) > S
TATUS
> A
LARMS
> A
LARM
H
ISTORY
Displays the alarm history for the T1 interface. An asterisk in a field indicates that an alarm has occurred
on the T1 interface since the last clear history.
I
NTERFACES
(T1[0]) > S
TATUS
> A
LARMS
> C
LEAR
H
ISTORY
Selecting this activator will clear the Alarm History for the T1 interface.
I
NTERFACES
(T1[0]) > T
EST
These options are used to initiate local and remote loopback tests and display the test status.
I
NTERFACES
(T1[0]) > T
EST
> L
OC
LB
Loopback of the local unit. Choices are
N
ONE
,
L
INE
, and
P
AYLOAD
.
L
INE
Loopback loops all of the received
data back toward the network. The transmitted data is the identical line code that was received, including
any bipolar violations.
P
AYLOAD
Loopback is similar to line loopback except that the framing is extracted
from the received data and then regenerated for the transmitted data.
N
ONE
disables the loopback test.
Default is
N
ONE
.
I
NTERFACES
(T1[0]) > T
EST
> R
EM
LB
Loopback of remote unit. Choices are
N
ONE
,
L
INE
, and
P
AYLOAD
.
L
INE
Loopback loops all of the received
data back toward the network. The transmitted data is the identical line code that was received, including
any bipolar violations.
P
AYLOAD
Loopback is similar to line loopback except that the framing is extracted
from the received data and then regenerated for the transmitted data.
N
ONE
disables the loopback test.
Default is
N
ONE
.
LOS
Loss of Signal. No signal detected on port interface.
RED
Not able to frame data received on the port.
Alternately referred to as Out of Frame (OOF).
YELLOW
Remote alarm indicator (RAI) being received on port.
BLUE
Receiving unframed all ones from the port alarm
indicator signal (AIS).
LOS
Loss of Signal. No signal detected on port interface.
RED
Not able to frame data received on the port.
Alternately referred to as Out of Frame (OOF).
YELLOW
Remote alarm indicator (RAI) being received on port.
BLUE
Receiving unframed all ones from the port alarm
indicator signal (AIS).
Summary of Contents for TOTAL ACCESS 600R
Page 4: ...4 2002 ADTRAN Inc 61200600L1 1A Revision History This is the first issue of this manual...
Page 16: ...Section 1 System Description Total Access 600R System Manual 16 2002 ADTRAN Inc 61200600L1 1A...
Page 128: ...Section 5 DLP Index Total Access 600R System Manual 128 2002 ADTRAN Inc 61200600L1 1A...
Page 134: ...134 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 002 Total Access 600R System Manual...
Page 138: ...138 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 003 Total Access 600R System Manual...
Page 144: ...144 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 005 Total Access 600R System Manual...
Page 152: ...152 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 007 Total Access 600R System Manual...
Page 160: ...160 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 009 Total Access 600R System Manual...
Page 180: ...180 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 015 Total Access 600R System Manual...
Page 190: ...Section 6 ADTRAN Utilities Total Access 600R System Manual 190 2002 ADTRAN Inc 61200600L1 1A...
Page 192: ...Section 7 MIB Total Access 600R System Manual 192 2002 ADTRAN Inc 61200600L1 1A...
Page 196: ...Section 7 MIB Total Access 600R System Manual 196 2002 ADTRAN Inc 61200600L1 1A...