Section 5 DLP-012
Total Access 600R System Manual
168
© 2002 ADTRAN, Inc.
61200600L1-1A
DLP-012
Perform Steps Below in the Order Listed
1. Connect to the unit using the RJ-45
CRAFT
interface.
If you are not already connected to the unit’s
CRAFT
interface (either with a
VT100 compatible terminal or with a PC running VT100 emulation software), follow the procedure in
DLP-001,
Connecting the Terminal or PC to the CRAFT Port
CRAFT
interface
limits the config transfer procedure to XMODEM Only.
2. Log in to the unit. (See DLP-002,
, for details.)
3. Go to the
S
YSTEM
U
TILITY
menu and select
C
ONFIGURATION
T
RANSFER
menu; press <Enter>
4. Set the
T
RANSFER
M
ETHOD
menu to
XMODEM
.
5. Select
L
OAD
AND
U
SE
C
ONFIG
to start the transfer. Enter Y to confirm the transfer and prepare the unit
for the transfer download.
When the unit is ready to receive the XMODEM configuration file, the menu screen will clear and
display
XMODEM/CRC: Transmit CONFIG file now...
If this does not appear, please review the
steps above for possible configuration errors.
6. From the terminal emulation software, begin the XMODEM transfer by using the appropriate command
sequence. For Windows HyperTerminal, select
T
RANSFER
>S
END
F
ILE
. Enter the filename (including
path) and select
XMODEM
as the
T
RANSFER
M
ETHOD
. Configuration files should have a .cfg extension.
If necessary, refer to the terminal emulation software documentation for help.
Because XMODEM data is being transferred in-band through the menu interface, the VT100 menus of
the unit will be inoperable from the
CRAFT
interface. You can cancel the update at any time within the
terminal emulation software. (Please consult the documentation provided by the terminal emulation
software to determine how to do this.)
7. After the config transfer is complete, the
C
ONFIG
T
RANSFER
menu will be displayed.
Follow-up Procedures
Once this procedure is complete, return to the procedure which referred you to this DLP and continue with
the tasks indicated there.
The following message is displayed: “Warning: WAN link may be reset after transfer
complete!”
Summary of Contents for TOTAL ACCESS 600R
Page 4: ...4 2002 ADTRAN Inc 61200600L1 1A Revision History This is the first issue of this manual...
Page 16: ...Section 1 System Description Total Access 600R System Manual 16 2002 ADTRAN Inc 61200600L1 1A...
Page 128: ...Section 5 DLP Index Total Access 600R System Manual 128 2002 ADTRAN Inc 61200600L1 1A...
Page 134: ...134 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 002 Total Access 600R System Manual...
Page 138: ...138 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 003 Total Access 600R System Manual...
Page 144: ...144 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 005 Total Access 600R System Manual...
Page 152: ...152 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 007 Total Access 600R System Manual...
Page 160: ...160 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 009 Total Access 600R System Manual...
Page 180: ...180 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 015 Total Access 600R System Manual...
Page 190: ...Section 6 ADTRAN Utilities Total Access 600R System Manual 190 2002 ADTRAN Inc 61200600L1 1A...
Page 192: ...Section 7 MIB Total Access 600R System Manual 192 2002 ADTRAN Inc 61200600L1 1A...
Page 196: ...Section 7 MIB Total Access 600R System Manual 196 2002 ADTRAN Inc 61200600L1 1A...