Chapter 6. Terminal Menu and System Control
6-14
ATLAS 800 User Manual
61200180L1-1
»» Current Update
Status
Read security: 5
Indicates progress or problems encountered during the current update pro-
cess. The field displays
Idle
if no update is in progress or when the update
is successfully completed. At the end of a successful update, the contents of
this field are copied into
Previous Update Status
.
If you are updating several modules at the same time (if
Module Slot
is set
to
All Modules of a Type
), this option displays
[+]
, indicating this field con-
tains submenu items. The following submenus display:
During the TFTP upload process, various status messages are provided in
Current Update Status
(see Table 10-1 on page 10-5).
»» Previous Update
Status
Read security: 5
Displays the status of the previous update. If a firmware update has not
been attempted for a particular slot, this field reads,
Has not been
attempted.
Following a successful update the field reads,
Module Update
Complete.
If an update was unsuccessful, the appropriate error message
displays.
»» Begin Firmware
Update
Write security: 1; Read security: 5
Begins updating the firmware for the selected modules. To start this action,
enter
Y
to begin or enter
N
to cancel. You can also cancel the operation after
the update has begun. For XMODEM updates, cancel the process via the
terminal emulation software (consult your documentation for information
Restart at Specified
Date and Time
Lets you specify a date and time to automatically
restart the updated module. (When you select this
option, a new field called
Restart Date and Time
displays below the current field.)
Restart Date and
Time
Write security: 1; Read security: 5
Defines the date and time to restart the system.
•
Enter the time using a 24-hour format (i.e.,
23:00:00 for 11:00 pm).
•
Enter the date in mm-dd-yyyy format (i.e., 10-
30-1998).
Restart at Specified Date and Time
is only available for the
System Controller— not for modules residing in expansion slots, since
they are unable to maintain normal operation during the update
process.
Slt
Indicates the slot number.
Type
Defines the type of module for each slot.
Current Status
Indicates the status of the current update.
Previous
Status
Indicates the status of the previous update.
Previous Time
Indicates the time of the previous update.
Summary of Contents for ATLAS 800 Series Module QUAD E1
Page 1: ...ATLAS 800 User Manual Part Number 1200180L1 Part Number 1200227L1 61200180L1 1B March 1999...
Page 12: ...xii...
Page 22: ...List of Tables xxii ATLAS 800 User Manual 61200180L1 1...
Page 28: ...Chapter 1 Introducing the ATLAS 800 1 6 ATLAS 800 User Manual 61200180L1 1...
Page 42: ...Chapter 3 Operating the ATLAS 800 3 6 ATLAS 800 User Manual 61200180L1 1...
Page 60: ...Chapter 5 Navigating the Terminal Menu 5 6 ATLAS 800 User Manual 61200180L1 1...
Page 94: ...Chapter 8 Dedicated Maps Terminal Menu 8 10 ATLAS 800 User Manual 61200180L1 1...
Page 122: ...Chapter 9 Dial Plan Terminal Menu 9 28 ATLAS 800 User Manual 61200180L1 1...
Page 162: ...Appendix A System Event Logging A 14 ATLAS 800 User Manual 61200180L1 1...
Page 166: ...Appendix B Troubleshooting B 4 ATLAS 800 User Manual 61200180L1 1...
Page 190: ......