When the ‘user1’ operator logs in, they will only see tabs configured for them.
example: user1 is does not view ‘System’, ‘Security’, ‘RD Services’,
‘RF Params’ and ‘Bars Tones & ID’ tabs after login as configured
If a user has ‘Write Access’ configured to ‘NO’, user will receive permissions error when
attempting to change any values.
Other security features
HTTP Port
The Web UI listening port or ‘HTTP Port’ may also be changed to prevent unwanted users from
finding the Adtec web interface at the default port. If the port is changed, the web address for
login will need updated.
For example if the unit IP address is 192.168.10.48, standard web navigation can occur by
typing http://192.168.10.48 in the browser address bar. If the port is changed (to 8000 for
example), then user would need to type http://192.168.10.48:8000 to navigate to the unit. All
requests on default HTTP port 80 would be denied.
Stealth IP address
The Stealth IP address feature allows up to 4 IP addresses as a ‘safe list’. Any IP addresses
listed in the ‘safe list’ are allowed to enter the box. Any IP addresses that aren’t listed will be
denied all access. When enabling this feature, it is recommended to enter the IP address of the
81
Summary of Contents for RD-71
Page 1: ...RD 71 10 bit 1080P Integrated Receiver Decoder USER GUIDE v2 02 10 1 ...
Page 5: ...Application Diagrams Turn Around and Service Filtering 5 ...
Page 6: ...Zixi IP Transport Zixi Link point to point or Zixi Receive point to multi point 6 ...
Page 9: ...6 NC No Connect 7 GND Ground 8 L Left 9 R Right 9 ...
Page 32: ...32 ...
Page 45: ...RF Params LB model 45 ...
Page 56: ...Bars Tones and ID 56 ...
Page 101: ...101 ...
Page 109: ...109 ...