![Adtec RD-71 User Manual Download Page 48](http://html.mh-extra.com/html/adtec/rd-71/rd-71_user-manual_2854109048.webp)
selected, the tuner/demodulator will determine the actual modulation type.
Symbol Rate Mode
-
Symbol Rate is defined for digital communications as the number of
symbols per second. The amount of data per symbol depends on the modulation type and
FEC code rate. Units for this field are expressed in MSym/s and the actual range is
determined by feature key. If zero [0] or AUTO is entered, the tuner/demodulator will
determine the actual symbol rate.
ISI
-
ISI (input stream identifier) is required for multistream applications. If a multistream
RF source is detected, BBHeaders containing this value will be demodulated and output to
the receiver. This value has no effect during single stream applications.
PLS Mode
- PLS Mode determines the Gold sequence code to use for descrambling.
DEFAULT (or 0), CODE1 (User entered sequence in ‘PLS Code 1‘) or CODE2 (User entered
sequence in ‘PLS Code 2’)
PLS Code 1
- User defined PLS Gold sequence code, active when PLS Mode set to ‘CODE1’.
PLS Code 2
- User defined PLS Gold sequence code, active when PLS Mode set to ‘CODE2’.
RF Params (PRX model)
48
Summary of Contents for RD-71
Page 1: ...RD 71 10 bit 1080P Integrated Receiver Decoder USER GUIDE v2 02 10 1 ...
Page 5: ...Application Diagrams Turn Around and Service Filtering 5 ...
Page 6: ...Zixi IP Transport Zixi Link point to point or Zixi Receive point to multi point 6 ...
Page 9: ...6 NC No Connect 7 GND Ground 8 L Left 9 R Right 9 ...
Page 32: ...32 ...
Page 45: ...RF Params LB model 45 ...
Page 56: ...Bars Tones and ID 56 ...
Page 101: ...101 ...
Page 109: ...109 ...