![ADT Commercial Fire & Burglary Alarm System FOCUS 200 PLUS Installation And Setup Manual Download Page 95](http://html1.mh-extra.com/html/adt/commercial-fire-and-burglary-alarm-system-focus-200-plus/commercial-fire-and-burglary-alarm-system-focus-200-plus_installation-and-setup-manual_2854006095.webp)
Section 10 – Access Control
10-9
Installing and Wiring the Electric Door Strike and Card/Key Reader (or Keylok)
Wiring Connections Between ACIU and Readers/Strike
Reader and Strike Wire Connections (1)
ACIU Terminal
Marlok
Keylok (2)
Marlok
Keyreader
(2)
Sensor
Engineering
(Epic)
Dorado (5)
Motorola
Indala
TB2-1 (-) (4)
Brown
Brown
Black
Black
Black
TB2-2 (+)
Green
Green
Red
Red
Red
TB2-3 (data “0”)
Orange
Orange
Green
Green
Green
TB2-4 (data “1”)
Black
Black
White
White
White
TB2-5 (LED “A”)
Violet
Brown
Brown
TB2-6 (LED “B”)
Brown
NOT USED
Blue
Orange
Yellow
Yellow
Blue
Orange
TB3-1 Strike (-)
Red (2a)
Red (2b) (3)
Strike (-)
Strike (-) (3)
Strike (-) (3)
Strike (-) (3)
TB3-2 Strike (+)
Yellow (2a)
330-ohm
Yellow (2b) (3)
Strike (+)
Strike (+) (3)
Strike (+) (3)
Strike (+) (3)
(1) To extend reach of card/key readers for connection to ACIU, use manufacturer’s extension cable or use 494461 Cable as noted
below.
(2) For Marlok applications:
a.
For a Marlok KEYLOK (comes with 5V internal solenoid), connect red and yellow keylok wires to TB3-1 and TB3-2,
respectively, and remove Jumper E11 in order to supply 5V to solenoid.
b.
For Marlok KEYREADER (works with the 12V stand-alone strike):
1.
Connect (+) and (-) terminals of strike to TB3-2 and TB3-1, respectively.
2.
Insert a 330-ohm +/- 5%, 1-watt resistor in series with the yellow wire from Keyreader to TB3-2.
3.
Connect red wire from Keyreader directly to TB3-1.
4.
Insert Jumper E11 to supply 12V.
(3) Strike requires 12VDC (E11 = IN). If not using strike, connect a 3K resistor across TB3-1 and TB3-2.
(4) Connect TB2-1 to CWG so that wire from reader will be returned to CWG.
(5) Cut resistor R8 on the ACIU circuit board, if you are using Dorado 7401 or 7901 card readers. See Figure 10-4.
Using 494461 (6466-10) Cable for Extension
1 BLK
6—BRN
2 RED
7—RED/BLK = Violet
3 BLU
8—BLU/BLK = Green
4 ORG
9—YEL/BLK = White
5 YEL
10—ORG/BLK
To install the electric door strike and card/key reader or Keylok, perform the following steps:
Step
Action
1
Install the electric door strike and the card/key reader or Keylok in accordance with the
manufacturer's instructions.
2
Run the wiring in accordance with manufacturer's instructions, making sure that all
wiring to the ACIU does not exceed 150' (see Figures 10-2 and 10-3).
Where vendor extension cables are not available for the connections, use 494461 (6466-10)
Cable for the extension.
3
Set the DIP switch settings for the card reader, as required.
4
If you are not using a strike or a Keylok, install a standard 3K EOL resistor across TB3-1
and TB3-2 on the ACIU to simulate the strike load for the strike supervisory circuit.
Summary of Contents for Commercial Fire & Burglary Alarm System FOCUS 200 PLUS
Page 2: ......
Page 22: ...FOCUS 200 PLUS Installation and Setup Guide 3 6...
Page 28: ...FOCUS 200 PLUS Installation and Setup Guide 4 6...
Page 64: ...FOCUS 200 PLUS Installation and Setup Guide 6 8...
Page 76: ...FOCUS 200 PLUS Installation and Setup Guide 7 12...
Page 110: ...FOCUS 200 PLUS Installation and Setup Guide 10 24...
Page 166: ...FOCUS 200 PLUS Installation and Setup Guide 16 4...
Page 196: ...FOCUS 200 PLUS Installation and Setup Guide 21 4...
Page 204: ...FOCUS 200 PLUS Installation and Setup Guide 22 8...
Page 210: ...Index Index 6...
Page 214: ...A 4...