Chapter 6 - Maintenance
70
Adept Cobra s600/s800 Robot User’s Guide, Rev H
NOTE:
The frequency of these procedures will depend on the particular
system, its operating environment, and amount of usage. Use the times in
as guidelines and modify the schedule as needed.
6.3
Checking Safety Systems
These tests should be done every six months.
1. Test operation of:
• E-Stop button on Front Panel
• E-Stop button on pendant
• Enabling switch on pendant
• Auto/Manual switch on Front Panel
NOTE:
Operating
any
of the above switches should disable High Power.
2. Test operation of any external (user supplied) E-Stop buttons.
3. Test operation of barrier interlocks, etc.
Check for signs of oil around of harmonic drive area.
3 months
.
Lubricate Joint 3 (Z-axis) ball screw
3 months
See
Replace Encoder battery
5 to 10 years
a
WARNING:
Lockout and tagout power before servicing.
WARNING:
The procedures and replacement of parts
mentioned in this section should be performed only by
skilled or instructed persons, as defined in
. The
access covers on the robot are not interlocked – turn off
and disconnect power if covers will be removed.
Table 6-2. Inspection and Maintenance
Item
Period
Reference
a
For robot models with the smaller, rectangular batteries, inspect the battery every 18
months to 3 years.
Summary of Contents for Cobra s600