![adept technology Cobra s600 User Manual Download Page 104](http://html2.mh-extra.com/html/adept-technology/cobra-s600/cobra-s600_user-manual_3047342104.webp)
Chapter 7 - Optional Equipment Installation
104
Adept Cobra s600/s800 Robot User’s Guide, Rev H
Figure 7-26. Joint 2 Menu - Upper Limits
8. In the next menu, enter the new value for the J2 upper limit softstop. See
9. Once you have modified the upper and lower joint limit softstops, you must save
the new values. Select option 0 => Exit, then select option 7 = Save ALL
specifications to system disk.
10. Reboot the system by cycling 24 VDC power to the SmartController. The new
joint limits will be in affect when the system reboot is done.