Table 16: Broadcast parameters — CU commands in lucDMC description
No.
Type Byte 3
Byte 2
Byte 1
8
Broadcast Parameter I 0xF0
MaxNoOfModules 0x99
0x11
FailSafeValue 0xAA
L2: 0x33-off, 0xCC-on
FailSafeTimeOut 0x33
NewFailSafeTimeOut(
HiByte)
9
Broadcast Parameter II 0x69
Remote Feedback Duration 0x33 NewDurationValue
(HiByte)
10
BroadcastParameter III (1 telegram) 0x66
WigWagSyncCMD 0x0F
0x22
No Byte 0
Remarks
Hints
Implemented in
remote
Downward
compatible
8
NewNoOfModules
Range: 3-127 (odd
no!), default 127
To be sent 3 times in a sequence
with a pause of 0.5s; in RU-II valid
only when received at least 2
times within 5 sec.
Yes
Yes
L1: 0x33-off, 0xCC-on
Default ON
Yes
Yes
NewFailSafeTimeOut(LoByte) Range: 5-3600 [s],
default 90
Yes
Yes
9
NewDurationValue (LoByte)
Yes
10 0xCC
Yes
Yes
RELIANCE Intelligent Lighting
Operation
80
Copyright
©
ADB SAFEGATE, All Rights Reserved
Summary of Contents for RELIANCE Intelligent Lighting Platform III
Page 1: ...RELIANCE Intelligent Lighting Platform III User Manual UM 5005 Rev 004 2020 08 06 ...
Page 2: ......
Page 10: ...RELIANCE Intelligent Lighting List of Figures x Copyright ADB SAFEGATE All Rights Reserved ...
Page 12: ...RELIANCE Intelligent Lighting List of Tables xii Copyright ADB SAFEGATE All Rights Reserved ...
Page 18: ...RELIANCE Intelligent Lighting Safety 6 Copyright ADB SAFEGATE All Rights Reserved ...
Page 52: ...RELIANCE Intelligent Lighting Introduction 40 Copyright ADB SAFEGATE All Rights Reserved ...
Page 56: ...RELIANCE Intelligent Lighting Installation 44 Copyright ADB SAFEGATE All Rights Reserved ...
Page 118: ......