2.7.6 RELIANCE IL Control and Communication Unit
Figure 2: RELIANCE IL Central Unit
The ADB SAFEGATE RELIANCE IL Control and Communication Unit (CU) represents the functions of a master unit competitors
sell. The Control Unit is — in contrast to competitor products — built into the ADB SAFEGATE Constant Current Regulator
type E (CCRE
®
) with RELIANCE IL III option. It is an optional Printed Circuit Board (PCB) in the CCR that is detected by the ADB
SAFEGATE CCR firmware. The CCR activates the RELIANCE IL SRU when the CU is detected. The Control and Communication
Unit listens the series circuit and collects the feedback from the remotes. The feedback is sent to the CCR as telegrams.
Figure 3: COSAL CCRE with RELIANCE IL Central Unit