This section explains how the regulator parameters can be adapted with lucDMC to be suitable for RELIANCE IL use. Do the
following to execute lamp failure measuring:
Check the condition of the series circuit for completeness and functionality.
Tip
There must not be defective lamps or open transformers installed into the circuit.
DANGER
Avoid provisional installations such as short-circuit plugs.
UM-5005, Rev. 004, 2020/08/06
71