Selecting ON in Show, the operator identification screen is enabled when the unit is
turned on. At this stage, this identification can be carried out or not, optionally, and what
is more, it allows the input of any alpha-numerical ID up to 16 characters.
The next option allows you to establish the obligation or not of carrying out the identifica-
tion:
Show
ON
Compulsory
ON
ISO 12176-3
OFF
Reset
OFF
Press the and keys to move to the desired option.
Use the or keys to shift from OFF to ON or vice
versa. ON enables the obligation and in turn makes
the operator’s identification in Show option shifts to
ON if it still happened to be OFF.
The identification is now obligatory but still allows the entry of any alpha-numerical ID up
to 16 characters.
The next option allows the operator’s ID to be established according to the ISO 12176-3
criteria in the fields of expiry date and skills (which allows for electrofusion processes),
language, etc.
Show
ON
Compulsory
ON
ISO 12176-3
ON
Reset
OFF
Press the and keys to move to the desired option.
Use the or keys to shift from OFF to ON or vice
versa. ON enables the application of criteria set in ISO
12176-3 and in turn makes the Show and/or Com-
pulsory options shift to ON if it still happened to be
OFF.
Apart from being obligatory, the identification must be carried out following the criteria
set out in the ISO 12176-3. Nevertheless, it does allow being introduced by means of a
barcode or manually using the keyboard.
Finally, the latest option Reset allows to establish the way to delete the operator’s
identification entered.
Show
ON
Compulsory
ON
ISO 12176-3
ON
Reset
ON
Press the and keys to move to the desired option.
Use the or keys to shift from OFF to ON or vice
versa.
Pressing ON deletes the operator’s ID every time the
unit is stopped whereas OFF only when a change of
date.
Press the <START> key to accept the selection made. Press the <STOP> key to exit the