USER MANUAL
BEAT HF
Edition: January 2016
Revision: No. 4
MODE OF USE -
31
Once the data have been successfully read, the unit will remain await for confirmation to
proceed. Press <STOP> to go back to the previous screen or <START> to continue.
dd/mm/yy
hh:mm
Scrapped & Clean
<Yes>
Confirm
Confirmation is requested of whether the scraping and
de-greasing of the pipes has been done.
Press <STOP> to go back to the initial screen of Fusion data or <START> to continue.
dd/mm/yy
hh:mm
Clamp
<Yes> <No>
Confirm
Confirmation is requested of whether a clamp mounted
on the pipes was used (for Tr model only).
The cursor remains positioned on <Yes> by default.
Press the
arrow to move it to <No>, depending on
the situation.
Press <STOP> to go back to the previous screen or <START> to continue.
nnnn
hh:mm
40.0 V 0075s 2.25
S
0072s
Press <START>
On the top line, the fusion parameters read from the
fitting’s barcode will be shown.
0072s:
Time of electrofusion (*)
(*) The time of the electrofusion can vary in relation to the nominal value due to the
correction of the room temperature, that being included in the barcode by the manufac-
turer of the fitting or being beyond the temperatures not rectified.
Press <STOP> to go back to the initial Fusion data screen or <START> to continue.
Go to clauses 3.4.5: Electrofusion cycle and 3.4.6: Possible interruptions in the
fusion cycle.
ã
C
Selecting the Manual fusion option:
Initial screen: Note for model BEAT HF-Tr: if the input of data related to Operator, Job,
Additional data and Traceability is disabled, or if enabled, once validated, the following
screen will appear:
nnnn
hh:mm
Fusion data
vvv V ff Hz tt
/
C
Read barcode
Press either the or arrow to select the Manual
fusion screen (see WARNING).
WARNING !
For model Tr the Manual fusion option could be disabled. If it is the case,
the unit will not be able to perform manual electrofusions.