3.5.3 Fusions option (for model BEAT HF-Tr only):
When the cursor on Fusions, press the <START> key.
Show
Export
Print
Erase
–
•
Press the and arrows to move to the desired
option and then press <START> to validate.
C
SHOW FUSIONS:
By validating the Show option, the last stored fusion in memory will be shown.
Barcode data entry:
Manual data input:
nnnn dd/mm/yy hh:mm
Coupler
1/n
AG d40 0056s 4.95
S
Correct fusion
The last fusion done is
shown on the screen.
Press the arrow to
see the previous fu-
sion.
nnnn dd/mm/yy hh:mm
Manual fusion
1/n
40.0V 0056s
Correct fusion
Top line
: Fusion number; date; start time.
Coupler/Fusion data
: Type of fitting or Manual fusion if the data has been
introduced manually.
1/n
: Screen number (information of the traceability). Press the
to see the following screens.
Fusion data
: Make (AG), diameter, electrofusion time and nominal
resistence or voltage and initial time of electrofusion if the
data has been introduced manually.
Result
: Correct fusion, Aborted, etc., according to the situation. For
the complete list of errors, refer to CHAPTER 4: TROUBLE-
SHOOTING.
Press either <STOP> or <START> to exit this option.
C
Export:
When validating the Export option the following options are given:
PENDRIVE-USB/A
PC-Serial
PC-USB/B
–
•
Press the and arrows to move to the desired
option and press the <START> key to validate.