MODE OF USE -
27
3.4
ELECTROFUSION PROCESS
3.4.1 Fitting connection:
Connect the unit cable connectors in the fitting terminals to be jointed. The contact
surfaces of both the fitting’s terminals and the cable connectors must always be clean.
NOTE !
We advise you to always use adapters, even
though the connection to the fitting may be
made directly. Doing so, the cable terminals are
protected, do not wear out, burn, etc.
It is recommend to refrain from electrofusion if the exterior temperature
is below -10
/
C or above +40
/
C.
3.4.2 Detection of possible initial errors:
Before the screen asking for the electrofusion data appears, the unit might detect the
following incidents:
C
Message of the state of the internal memory (BEAT HF-Tr only):
If there are 50 or less entries left before the memory is full, the following message will
appear:
dd/mm/yy
hh:mm
Remaining fusions xx
Confirm
Where xx corresponds to
#
50 fusion entries.
Press the <START> key to go to the next screen.
C
Input voltage/frequency outside margin:
With the unit on the initial screen, a check is done of the input voltage.
nnnn
hh:mm
Fusion data
vvv V ff Hz tt
/
C
Read barcode
Where the following information appears:
nnnn:
Fusion number
hh:mm:
Time
vvv V ff Hz: Input voltage and frequency
tt
/
C:
Room temperature
If the voltage registered by the unit were below or above the permitted tolerance (180-
270 V for nominal of 230 Vac), the following messages will appear on the display screen
(depending on the case):