IX - USING THE DEVICE
Important:
- Do not disconnect the micro-motor cord or
the scaler cord when the device is switched
on and the footswitch is pressed.
- Do not disconnect the micro-motor or the
ultrasonic handpieces when the device is
switched on and the footswitch is pressed.
- Do not engage the instrument to or disengage
it from the contra-angle when the micro-
motor is running.
- Do not screw or unscrew tips when the
handpieces are on.
- All accessories must be sterilized before use.
- For your safety and that of your patient, the
I
MPLANT
C
ENTER
must not be used with
accessories other than those supplied by
SATELEC.
- Check the integrity of the device and its
accessories before and after each use in order
to detect any problem.
- If necessary, do not use the device and
replace any faulty component.
The I
MPLANT
C
ENTER
is prepared for use as follows:
- Make sure that the device is connected
correctly and properly insulated.
- Switch the power switch (Fig. 2-5) to position I
(power on).
- Suspend bottles or bags of physiological saline
from the brackets.
- Raise the irrigation pump covers.
- Insert the irrigation line cassettes horizontally
into their housings.
- Close the covers.
- Insert the irrigation line perforating pins into
the bottles or bags of physiological saline.
- Raise the LCD screen.
- Adjust the angle of the LCD screen according to
the position of your device and your angle of
view.
- Make any necessary setting adjustments
(irrigation flow rate, speed, torque, power,
power mode, program, etc.) (refer to chapter
7).
Note
: This sequence must be completed in a
controlled asepsis context for the safety of your
patients. An operating assistant may be needed.
I-S
URGE
function
- Check that there are no traces of moisture on
the I-S
URGE
micro-motor or micro-motor cord
connections. Remove any moisture by wiping
and by blowing using the multifunction syringe
fed with medical quality filtered air.
- Connect the micro-motor cord to the left
connector of the device (Fig. 1-8).
- Align the micro-motor and cord connector
electrical contacts, then screw the motor onto
the connector.
- Connect a contra-angle to the I-S
URGE
micro-
motor.
- Fit an instrument (drill, bur, etc.) to the contra-
angle.
- Fasten the irrigation line to the cord using line
clips.
- Connect the end of the irrigation line to the
contra-angle.
- Run the motor fitted with its contra-angle and
its instrument without irrigation at moderate
speed for 10 to 15 seconds in order to spread
the lubricant and eliminate excess.
- Prime the irrigation circuit by pressing the
control keypad Flush button (Fig. 3-1).
- When the irrigation solution reaches the end of
the contra-angle, release the footswitch.
- Use the I
MPLANT
C
ENTER
in accordance with good
dental practice.
16