5. Setting up the device
15
Rounding of display values,
round:
Default:
00001
This function is for instable display values, where the display value is changed in
increments of 1, 5, 10 or 50. This does not affect the resolution of the optional outputs. With
[P]
the selection is confirmed and the device changes into menu level.
Definite contstant value,
const
:
Default:
0
The constant value can be evaluated via the alarms or via the analog output, like the current
measurand. The decimal place cannot be changed for this value and is taken over by the
current measurand. Like this a setpoint generator can be realised via the analog output by this
value. Furthermore it can be used for calculating the difference. At this the constant value is
substracted from the current measurand and the difference is evaluated in the alerting or by the
analog output. Thus regulations can be displayed quite easily.
Zero point slowdown,
ZErO:
Default:
00
At the zero point slowdown, a value range around the zero point can be preset, so the display
shows a zero. If e.g. a 10 is set, the display would show a zero in the value range from -10 to
+10; below continue with -11 and beyond with +11. The maximum adjustable range of value is
99.
Sliding average determination,
AVG:
Default:
1.0
Here, the number of the meterings that need to be averaged is preset. The time of averaging
results of the product of measuring time
SEC
and the averaged metering
AVG
. With the selection
of
AVG
in the menu level
DISPL,
the result will be shown in the display and evaluated via the
alarms.
Arithmetic,
ArItH:
Default:
n0
With this function the calculated value, not the measuring value, is shown in the display. With
no
, no calulation is deposited. With
[P]
the selection is confirmed and the device changes into
menu level.
Parameterisation level
Menu level
Reciprocal
Root
extraction
Square