12
10
5. Setting up the device
Activation / deactivation of the programming lock or completion of the standard
parameterisation with change into menu group level (complete function range),
run:
Default:
uloc
With the navigation keys
[
▲
] [
▼
]
, choose between the deactivated key lock
Uloc
(works
setting) and the activated key lock
Loc
, or the change into the menu group level
ProF
. Confirm
the selection with
[P]
. After this, the display confirms the settings with
"
- - - - -"
, and automa-
tically switches to operating mode. If
Loc
was selected, the keyboard is locked. To get back into
the menu level, press
[P]
for 3 seconds in operating mode. Now enter the
CODE
(works setting
1
2 3 4
) that appears using
[
▲
] [
▼
]
plus
[P]
to unlock the keyboard.
FAIL
appears if the input is
wrong. To parameterise further functions
ProF
needs to be set. The device confirms this setting
with
„
- - - - -
„
and changes automatically in operation mode. By pressing
[P]
for approx. 3
seconds in operation mode, the first menu group
InP
is shown in the display and thus confirms
the change into the extended parameterisation. It stays activated as long as
ULOC
or
LOC
is
entered in menu group
RUN
.
Parameterisation level
Menu level
5.3. Programming interlock „
RUN
“