5.3 Operating Without Spare Drives
The following are guidelines for disk failure recovery when a spare drive is not available:
• Depending on the design of the system, it may be possible to remove a defective drive and
replace it with a new drive without shutting down the system (hot-swapping). Alternatively,
the system can be shut down at a convenient time and the system administrator can replace
the failed drive.
• If the replacement drive is installed on the same channel and ID, you can then proceed with
data rebuilding.
• If the replacement drive is installed on a different channel or ID, you need to scan in the new
drive first then assign it as a spare drive of the logical drive which has had a drive failure. Data
rebuilding will have to be manually initiated.
Important
Although the RAID system provides uninterrupted disk access even after a disk failure, do not leave
a failed drive unattended to. Without replacement, the system will not survive a second physical
drive failure on the same logical drive. A defective drive must be promptly replaced and data
rebuilt.
Caution
When performing hot-swapping, be sure to remove only the defective drive. Removing the wrong
drive will result in complete, unrecoverable data loss. Use the Enclosure window or Physical View
to locate exactly which physical drive has failed.
5.4 Before You Start
Altos RAIDWatch Manager comes with password protection that prevents unauthorized
modification of the disk array configuration. During each attempt at modifying the system
configuration, the configuration will be password protected.
By default, Altos RAIDWatch Manager station comes without any password. For information on
how to set a password and other security features, see section 3.4, ”Secondary Agent Settings”, on
page 36.
Summary of Contents for Altos RAIDWatch
Page 1: ...Isssue 2 0 1 May 2004 ...
Page 8: ...viii ...
Page 13: ...Preface xiii ...
Page 14: ...Altos RAIDWatch User Guide xiv ...
Page 44: ...Altos RAIDWatch User Guide 30 ...
Page 60: ...Altos RAIDWatch User Guide 46 ...
Page 84: ...Altos RAIDWatch User Guide 70 ...
Page 88: ...Altos RAIDWatch User Guide 74 ...
Page 98: ...Altos RAIDWatch User Guide 84 ...
Page 148: ...Altos RAIDWatch User Guide 134 ...
Page 158: ...Altos RAIDWatch User Guide 144 ...
Page 169: ...The NPC 155 2 Two levels Warning and Alert 3 Only the most serious events Alert messages ...
Page 170: ...Altos RAIDWatch User Guide 156 ...
Page 186: ...Altos RAIDWatch User Guide 172 ...
Page 196: ...Altos RAIDWatch User Guide 182 ...
Page 202: ...Altos RAIDWatch User Guide 188 ...
Page 206: ...Altos RAIDWatch User Guide 192 ...
Page 212: ...6 ...