91
10.12.5. Detector signal strength
Make the detector signal strength test in the same way as the walk test.
The signal strength displayed corresponds to the reception strength of
the last received signal of this detector. For the test, the reception
strength of the alarm panel is reduced by 6dB. The signal strength
should be higher than
3
to ensure radio communication. If the detector
signal is to weak, use a
Repeater (WAM)
to ensure good radio
communication.
10.12.6. External sounder
The test of the external siren is used for displaying the signal strength.
The signal strength should be higher than
3
.
10.12.7.WAM Signal
The test of the WAM signal is used for displaying the signal strength. The
signal strength should be higher than
3
.
10.12.8. Arming station
The test of the arming station signal is used for displaying the signal
strength. The signal strength should be higher than
3
.
10.12.9. Outputs
The test of the outputs is used for displaying the signal strength. The
signal strength should be higher than
3
.
10.12.10. Telecommands
Press the buttons of the telecommands. The alarm panel shows which
button was pressed and what the button is used for. The display shows
the identity and user of the telecommand
10.12.11. Pendant
Press the button on the pendant. The display shows the identity and
user assigned to the pendant.
The test of the pendant is used for displaying the signal strength. The
signal strength should be higher than
3
.
10.12.12. Panic alarms
Press both buttons on the panic alarm transmitter. The display shows the
identity of the user assigned to the panic alarm.
The test of the panic button is used for displaying the signal strength.
The signal strength should be higher than
3
.
10.12.13. Proximity tag
Hold the tag in front of the alarm panel. If the tag is detected, the
panel shows the user to which the tag is assigned. Only one tag can be
trained for each user. You assign a tag to a user in user mode.