71
10.10.1.14 Static Test Call
In static testing the system makes a test call either at one particular
time of day or on one day every month.
To make test calls at a set time every day select
Reporting, Alarms, Static Test Call, Daily.
From the display select a
number between 01 and 24 to choose the time of day for the call.
For example, select 18 to program the radio alarm panel to make a
static test call at 6:00pm every day.
To make test calls on one day every month select
Reporting, Alarms, Static Test Call, Monthly.
From the display select a
number between 1 and 31 to specify the day of the month on which
the call should take place. The radio alarm panel will make a test
call at 1am on the selected day.
Note that the radio alarm panel will add or subtract up to 16
minutes at random to the time you specified. This is to make sure
that the ARC is not overwhelmed with a flood of test calls from
systems that have all been given the same time.
Select
Reporting, Alarms, Static Test Call, Disabled
to disable static test
calls.
10.10.1.15. Burg Comms Rearm
Press the control button
to select
Burg Comms Rearm
and confirm
by pressing the control button
under the word
Select
. To cancel
input, press the control button
under the word
Back
.
If you confirm
Burg Comms Rearm
with the
Select
button, you see the
following graphic display:
Use the control buttons
to select whether the panel is to reset
channel 3 pf the Fast Format report following expiry of the delay time
and then rearm it if there is a new alarm. If this function is enabled, all
zones in alarm state are hidden. If the function is enabled, this channel
is disabled until the panel is deactivated and rearmed. Select a
function by pressing the control button
under the word
Select
.
To
cancel input, press the control button
under the word
Back.