22
10.3.3 Selecting partitions
After entering the
zone typ
e, use the control buttons
to select
Partitions
. Confirm your selection by pressing the control button
under the word
Select
. To cancel input, press the control button
under the word
Back
.
If you confirm
Partitions
with the
Select
button, you see the following
graphic display:
Use the control buttons
to select the
partition
in which this zone is
to be monitored. At least one partition must be marked with
Yes
. For a
list of partitions and their attributes, see page 13 of these instructions.
Change the setting by pressing the control button
under the
word
Change
. To end input, press the control button
under the
word
Done
.
When you first teach a detector to the radio alarm panel then the zone
defaults to partition 1.
You can assign zones of the following type to one or more partitions:
Normal Alarm, Final Exit, Entry Route, Key Box, and Exit Normal Alarm.
Note: If you intend to use part set partitions then make sure that for any
zone shared by more than one
partition the part set options are all the same
.
The radio alarm panel will not allow you to assign zones of the following
types to more than one partition: 24 Hour, Fire, Panic Alarm, and
Technical.
10.3.4 Selecting zone attribute
After entering the
partition
, use the control buttons
to select
Attributes
. Confirm your selection by pressing the control button
under the word
Select
. To cancel input, press the control button
under the word
Back
.
If you confirm
Attributes
with the
Select
button, you see the following
graphic display:
Use the control buttons
to select the function you want to assign
to this zone. Change the setting by pressing the control button
under the word
Change
. To end input, press the control button
under the word
Done
.
Attributes
Meaning
Chime
When this zone is triggered in deactivated state, the
panel emits an acoustic signal (door chime).
Soak test
If a detector triggers a false alarm, activate the
detector test. For further information, see the section
“Test Function” in these operating instructions under
“Walk test”.
Activity Mon.
The detector function is inverted. An alarm is
triggered at the panel if the detector reports no
alarm within a specific period.
Part Set
This zone is monitored if the partition of this zone or all
partitions are internally activated.
Force Omit Set
This zone is automatically omitted if the zone is still
open when the panel is set.