72
10.10.1.16.
Send Tamper as Burg
Use the control buttons
to select
Send Tamper as Burg
.
Confirm
your selection by pressing the control button
under the word
Select
. To cancel input, press the control button
under the word
Back
.
If you confirm
Send Tamper as Burg
with the
Select
button, you see the
following graphic display:
Use the control buttons
to select whether the panel is to transmit
a tamper alarm as a burglar alarm. This is important since there are
stations that cannot evaluate the resetting of a tamper alarm. If this
function is enabled, a tamper alarm is sent as a burglar alarm (BA for
SIA or 130 for Contact ID). Select a function and confirm by pressing the
control button
under the word
Select
.
To cancel input, press the
control button
under the word
Back.
10.10.2. Social Care
NOTE: This option needs only to be programmed if you want to
transmit an alarm via digital protocol. If you want to send a speech
message, please select the next option.
The radio alarm panel sends a social care alarm message for the
following types of alarm:
Emergency
A user presses a button on a pendant. The radio alarm panel then
reports to the social care station with an EMERG BUTTON event
(SCANCOM channel 2).
Activity
A zone with the Activity Monitoring attribute has been triggered. While
the system is unset the radio alarm panel checks that this zone is
reporting activity. If the zone is quiet for longer than a pre-
programmed time then the radio alarm panel starts a medical alarm
and reports to the social care station with an INACTIVITY event
(SCANCOM channel 3).
If the system is set then the Activity Monitoring zone acts as a normal
alarm.
Press the control button
to select
Social Care
and confirm by
pressing the control button
under the word
Select
. To cancel
input, press the control button
under the word
Back
.
If you confirm
Social Care
with the
Select
button, you see the following
graphic display: