If you wish to remove a WAM from service in the system, then:
1. Select
Other Devices – WAM – Add/Del WAM
.
The display shows a list of the available WAMs.
2. Select the WAM you wish to delete. (When a slot is occupied with
a WAM the then line shows a
icon.)
The display asks you to confirm your choice.
3. Press SELECT.
The radio alarm panel deletes the WAM’s identity from the selected
memory slot.
If you confirm View
WAM
with
Select
, you see the following graphic
display:
When you teach the WAM, it also transmits its programming so that you
can see under View
WAM
the function in which the WAM has been
trained.
Function
Meaning
Not used
The WAM has been trained but is not used.
Repeater Module
Radio signals received from trained radio
detectors (trained in the WAM) are forwarded
to the panel following reception.
Output Module
Up to four relays of the WAM can be activated
from the radio alarm station, depending on
programming.
T/R Module
Technology
sender/receiver
module
for
connecting wired detectors (water detectors)
or a block lock / key switch.
Sounder Module
For connecting a wired external radio siren or
compact alarm device.
IMPORTANT:
See the WAM product instructions for operating and
programming the WAM.
10.5.3.1 WAM as radio repeater
If the WAM is trained with radio repeater function, you also have to
train the radio repeaters whose signals are to be transmitted via this
module to work with the WAM. Read the operating instructions of the
WAM.
10.5.3.2 WAM as output module
If the WAM is trained with output function, the panel automatically
reserves the respective outputs for this module in the station.
Outputs 31–34 for WAM 1
Outputs 15–18 for WAM 5
Outputs 27–30 for WAM 2
Outputs 11–14 for WAM 6
Outputs 23–26 for WAM 3
Outputs 07–10 for WAM 7
Outputs 19–22 for WAM 4
Outputs 03–06 for WAM 8
You do not have to add these outputs manually. Just make the settings
for the output functions as described in the section
Editing outputs
.
Outputs reserved by the WAM are described as shown in the following
diagram. Although you have to configure these outputs, you do not
have to add them.
Reserved
outputs by