10.7.12. Supervision Fail Response
Use the control buttons
to select
Supervision
.
Confirm your
selection by pressing the control button
under the word
Select
. To
cancel input, press the control button
under the word
Back
.
If you confirm
Supervision
with the
Select
button, you see the following
graphic display:
Use the control buttons
to select a function as described in the
table below. To select a function, press the control button
under
the word
Select
.
To cancel input, press the control button
under
the word
Back.
If there is no status message from a detector for more than two hours
the radio alarm panel raises an alarm.
:
Function
Meaning for activated
system
Meaning for
deactivated system
Disabled
No response
No response
Fault
Fault is reported by
telephone.
Fault is reported on
display and by signal
tone.
Tamper
External alarm
Transmission of
supervision failure and
tamper
Fault is reported on
display and by signal
tone.
External alarm
Transmission of
supervision failure and
tamper
Alarm
External alarm
Transmission of
supervision failure and
alarm
Alarm message on
display and signal tone
If the alarm system must meet EN50131-3 radio supervision requirements
then enable Supervision. Once enabled, the radio alarm panel will
prevent the user from setting the system if a detector has lost contact
with the radio alarm panel for more than 15 minutes.