Maintenance |
61
Code Error description
Effect
Action
F100
[...]
F106
Other error
Charging may not be
possible
Update the wallbox’s software using the
ABL
Configuration App
Check WLAN coverage on site
Check LAN cabling
Perform restart by pressing reset push button
(< 3 seconds)
F120
[...]
F123
Energy meter error
Charging may not be
possible
Check internal RCCB for the charge point
Perform restart by pressing reset push button
(< 3 seconds)
If the error or warning cannot be remedied or reset by one of the measures described above, switch off the power
to the wallbox(es) for about two (2) minutes via the MCB connected upstream in the domestic power distribution.
If the error or warning still cannot be remedied or reset even after doing this, contact
ABL Customer Service
Maintenance
Except for testing the integrated or upstream RCCBs, the Wallbox eM4 Twin is basically maintenance-free. However,
we still recommend the wallbox is regularly cleaned and the function of its charging sockets checked:
Use only a dry cloth for cleaning the wallbox. Do not use aggressive cleaning agents, waxes or solvents (such as
cleaning fluid or paint thinner) as they may dull the surfaces and indicators of the wallbox.
The wallbox must under no circumstances be cleaned with a pressure cleaner or similar device.
Check the charging sockets of the wallbox at regular intervals for any defects, damage or mechanical wear.